Picture of the authorMenu
icon

Selectra ProM Lite

Selectra ProM Lite

Fully open system. Low operating costs. Minimal reagent consumption. Economical usage of reagents. Quick patient data entry.

Together with the ELITech Clinical System S.A.S. line of ready-to-use reagents, the Selectra ProM Lite provides a complete integrated solution for a wide variety of laboratories. General technical characteristics of Selectra ProM Lite: - Capacity: up to 180 photometric tests/hour. - Reagent system: cooling the disk with reagents to a temperature of 2-10 °C under normal laboratory conditions. The reagent rotor has 32 positions for 10 ml, 25 ml and 50 ml reagent vials. Identification of reagents, automatic programming of samples, calibrators using a barcode scanner. Typical consumption of reagents is 250 μl per 1 test. All reagent positions can be programmed as P1, P2 and P3. Preheated needle, level detector and stirrer. - Sample system: the sample rotor has an external segment for 50 positions readable by the barcode scanner. Internal segment for 12 additional positional. All positions for 13 x 75 mm primary and secondary tubes, and pediatric cups. Continuous reloading of samples. All positions can be used for Calibrators, Controls, Normal, Pediatric and Emergency samples. Sample volume 2 - 30 μl per test, programmable in 0.1 μl increments. Sample needle with level detector, integrated mixer and anti-collision protection. Programmable ratios from 1:5 to 1:200 in equal increments, with 3 possible diluents. - Measuring disk: a reusable rotor with 48 cuvettes and an optical path length of 7 mm. The minimum measurement volume is 220 μl. The measurement temperature is 37°C, controlled by Peltier elements. - Lite source: quartz-iodine lamp 12V-20W. - Optical range: 340 – 700 nm. Automatic selection of the wavelength on the 8-position carousel of Lite filters (340, 405, 505, 546, 578, 620, 660 and 700 nm). - Photometric range: from -0.1 to 3.0 OA (Absorption Units). - Analytical modes (mono, two and three reagent systems): kinetic measurement with linearity check. Mono and bichromatic endpoint with or without bichromatic reagent blank and/or sample blank correction. Measurement at 2 points. Graphic display of all measured points. Automatic repetition of the measurement with a decrease in the sample volume. Non-linear calibration curves. Prozone check for immunological tests. Cutoff rule. - Quality control: up to 15 controls, 3 for 1 test. Westgard rules. Levy-Jennings graphs. - Water consumption: up to 0.5 l per hour during operation. - Interface languages: English, Russian. - Size: 120 x 75 x 61 cm (W x H x D). Weight: 95 kg. - Computer: based on an Intel® processor. Operating system: MS Windows™

Download PDF